Carrier 27VNA3

Checked against 27VNA3 Infinity Variable Speed Heat Pump with Greenspeed Intelligence — Product Data, September 2026.

Heat pump on R-454B, 3 to 5 ton. Here is what the Carrier documents say you can keep.

27VNA3 is a model family. The data plate on your unit carries a longer number that starts with 27VNA3 — the size and revision digits follow it. This page covers the family.

What you can keep

Indoor coil

Has to be replaced

Your existing R-410A indoor coil cannot stay. Carrier states that full furnace coils are not interchangeable and that the refrigerant the indoor coil is designed for must match the outdoor unit's.

Not checked: your own coil against this unit. That needs its model number, which is on the coil label inside the air handler or furnace cabinet.

Carrier's brand rule — see the brand page.

Line set

Can stay, with conditions

Your copper can normally stay. Carrier says there is no system-side reason to replace a line set, because R-454B uses the same POE oil as R-410A — but it puts the decision under your building code.

  • The line set continues to meet the local building code in force, which is what Carrier makes the reuse conditional on.
  • In high-rise buildings, Carrier states that fire breaks will be required on the refrigerant run.

Not checked: your line size. The 27VNA3 uses 3/8" liquid with 7/8" or 1-1/8" suction, by capacity, and you have not measured the outside diameter of both copper lines.

Carrier's brand rule — see the brand page.

Furnace

Can stay

Your existing gas furnace does not have to be replaced and needs no add-on kit. Carrier states that the dissipation control intercepts the signal from the thermostat and the furnace otherwise operates exactly as designed.

Carrier's brand rule — see the brand page.

Check your own coil and line set →

Sizes and line diameters

From the 27VNA3 product data, size by size. The last two columns are what the 25VNA4 on the pad today was installed with, at the same capacity.

Model Capacity Liquid line OD Suction line OD 25VNA4 liquid 25VNA4 suction
27VNA336A003 3 ton 3/8" 7/8" 3/8" (same) 7/8" (same)
27VNA348A003 4 ton 3/8" 1-1/8" 3/8" (same) 1-1/8" (same)
27VNA360A003 5 ton 3/8" 1-1/8" 3/8" (same) 1-1/8" (same)

How Carrier lists this unit

Tier Infinity
Compressor variable-speed
Region All regions
Coastal option Not listed
Controls Infinity fully communicating

The guide also offers this heat pump as the alternative to the R-410A 24VNA6 air conditioner.

What the documents say about this model

ManufacturerThe family does not use one compressor. Its physical data gives the 3 and 4 ton a variable speed rotary compressor and the 5 ton a variable speed scroll, under a single model name and a single tier. The 3 ton also runs a slower fan, 200 to 750 rpm against 200 to 800 on the other two, and carries eight condenser coil circuits where they carry nine.

Carrier — 27VNA3 Infinity Variable Speed Heat Pump with Greenspeed Intelligence — Product Data (27VNA3-01PD), printed page 3. Read 2026-09-04.

ManufacturerHow far above the indoor unit this one may sit depends on which size is quoted. With the outdoor unit above, the 5 ton is allowed 200 feet of vertical separation and the 3 and 4 ton only 100 — the sheet prints that split inside a single cell of its table. Below the indoor unit every size stops at 80 feet.

Carrier — 27VNA3 Infinity Variable Speed Heat Pump with Greenspeed Intelligence — Product Data (27VNA3-01PD), printed page 4. Read 2026-09-04.

ManufacturerIts service valve is 7/8 inch on all three sizes, while the tube the unit is rated on is 1-1/8 inch at 4 and 5 tons. On those two the fitting at the cabinet is a full size under the copper that runs to it, so measuring at the valve would understate the line by one size.

Carrier — 27VNA3 Infinity Variable Speed Heat Pump with Greenspeed Intelligence — Product Data (27VNA3-01PD), printed page 3. Read 2026-09-04.

ManufacturerOf its three sizes the 3 ton is the one that suffers most from thin copper, because it is the only one rated on a 7/8 inch line rather than 1-1/8. At 100 feet of equivalent length it gives up 8.2 percent of cooling capacity on a 5/8 inch line and 3.4 percent on 3/4, against 1.8 percent on the size it is rated for.

Carrier — 27VNA3 Infinity Variable Speed Heat Pump with Greenspeed Intelligence — Product Data (27VNA3-01PD), printed page 4. Read 2026-09-04.

ManufacturerIts own sheet rates it further for cooling than for heating: up to 23 SEER2 against up to 9.5 HSPF2, with heating operation stopping at -13F outdoor ambient. The compressor modulates from 20 to 100 percent of capacity, and on the 3 ton that reaches the ductwork as a cooling airflow spanning 325 CFM at the bottom of comfort mode to 1,200 at the top of efficiency mode.

Carrier — 27VNA3 Infinity Variable Speed Heat Pump with Greenspeed Intelligence — Product Data (27VNA3-01PD), printed page 1. Read 2026-09-04.

The rest of the answer above is Carrier's brand-wide rule — 8 cited statements, written out in full on the Carrier rules page.

Approved and certified combinations

We have not yet read a published match list for this unit. Ask your installer for the AHRI certified reference number of the combination they are quoting — every certified pair has one.

What this unit replaces

The 27VNA3 is the R-454B successor to 25VNA4. If that is what is on the pad today, this is the unit being quoted to you.

What to ask your installer about the 27VNA3

  1. The 27VNA3 takes 3/8" liquid with 7/8" or 1-1/8" suction, by capacity. Which capacity are you quoting me, and does my existing copper match the diameters for it?

The questions to ask about any Carrier swap are on the Carrier rules page.

Other Carrier heat pumps

Model Tier Compressor Replaces
27SPA6 Performance single-stage 25SPA5
27TPA8 Performance two-stage 25TP(A,B)7
27VNA0 Infinity variable-speed 25VNA8
37MUHAQ Performance variable-speed 38MURAQ**AB3
37MURAQ Comfort variable-speed 38MURAQ**AA3
27SCA5 Comfort single-stage 25SCA5, 25HCE4

Read next

This is a starting point, not an approval. Everything here is read from published manufacturer documents and dated, but only the licensed contractor who signs your installation can approve a specific system for your home and your local code. Take the citations on this page to them and ask.