What replaced the Carrier 25VNA8?

Checked against 25VNA8 Infinity 18VS Variable Speed Heat Pump — Product Data, September 2026.

The 25VNA8 is an R-410A heat pump — Carrier's Infinity tier, five-stage. R-410A equipment stopped being manufactured after 31 December 2024, so there is no new one of these to buy — but that does not mean your only option is a whole new system.

The model Carrier points you at

The guide maps the R-410A Infinity heat pumps to three Puron Advance models as a group. It does not pair them one to one.

The copper you already have

What the 25VNA8 was installed with, size by size. The last two columns are what the 27VNA0 needs at the same capacity, so you can see before the quote arrives whether your line set carries over.

Model Capacity Liquid line OD Suction line OD 27VNA0 liquid 27VNA0 suction
25VNA813 1 ton 3/8" 3/4" (—) (—)
25VNA824B 2 ton 3/8" 3/4" 3/8" (same) 3/4" (same)
25VNA824A 2 ton 3/8" 7/8" 3/8" (same) 3/4" (smaller)
25VNA825 2 ton 3/8" 7/8" 3/8" (same) 3/4" (smaller)
25VNA836 3 ton 3/8" 7/8" 3/8" (same) 7/8" (same)
25VNA837 3 ton 3/8" 1-1/8" 3/8" (same) 7/8" (smaller)
25VNA848 4 ton 3/8" 1-1/8" 3/8" (same) 7/8" (smaller)
25VNA860 5 ton 3/8" 1-1/8" 3/8" (same) 1-1/8" (same)

Whether your indoor coil, your copper and your furnace can stay is a Carrier rule rather than a rule about this model: the Carrier rules page states all three, with the documents behind them.

A like-for-like R-410A outdoor unit, labelled "For Service Only", is still a legal option in most states and keeps your existing coil — the phase-out guide sets out when that route closes .

How Carrier listed the 25VNA8

Refrigerant R-410A
Tier Infinity
Compressor five-stage
Region All regions
Coastal option Not listed

What the documents say about this model

ManufacturerTwo units in this family are both stamped 24. They differ by one letter — 24A and 24B — and they do not take the same copper: the B is on a 3/4 inch vapour line and the A on 7/8. Reading the capacity off the data plate and stopping there gets the line size wrong on one of them, and the letter that decides it looks like a build code.

Carrier — 25VNA8 Infinity 18VS Variable Speed Heat Pump — Product Data (25VNA8-04PD). Read 2026-09-02.

ManufacturerCarrier's headline sound figure for this family, 55 dBA, is the level in low speed with the Silencer System II — not the level at full output. A variable-speed heat pump spends most of its running hours at part load, which is what makes that the useful number, but it is not the number to expect on the coldest night of the year.

Carrier — 25VNA8 Infinity 18VS Variable Speed Heat Pump — Product Data (25VNA8-04PD). Read 2026-09-02.

Where the mapping comes from

DistributorCarrier Enterprise's 2025 equipment transition guide lists the 25VNA8 as an R-410A Infinity-tier heat pump: a five-stage unit, sold for all regions. No coastal option is listed. The guide's Puron Advance column for this row is the 27VNA0.

Carrier Enterprise — 2025 Carrier Equipment Transition Guide — A2L Refrigerant Ready (Rev.3 - 11/2024). Read 2026-09-01.

Read next